My shed floor heaved up after the thaw and now the door won't close
I built a 10x12 shed two summers ago on a gravel pad and everything sat fine until last week. After all that snow melted, the floor near the door bubbled up about an inch and a half and the bottom corner of the door drags so bad I have to shoulder it shut. Turns out I never tied the pad into any kind of drainage and the meltwater just sat under the front edge. I got a 6 foot trench dug and some crushed stone in so far, but I'm not sure if I should pull the floor boards and re-level or just live with it until fall. Has anyone fixed a heave like this without tearing the whole floor out?